PROBLEM: Second Scheduled Event or Group Playback using Modem fails.
Last reviewed: February 07, 2002
Article ID: 020207sab
The information in this article applies to:
- Pronto for Windows release 5.07 and all earlier versions.
Symptoms
Any of the following:
- A second scheduled event that connects to a Logger using a modem fails.
- A second Playback in a Group Playback using a modem fails.
Cause
The default time that Pronto for Windows allows between hanging up the modem
and dialling out for a second time is too short. When Pronto for Windows disconnects
from a Logger it waits for one second before processing continues. If data is
saved very quickly or if the event is a Playback to MDM file or a Check of Logger
Status event the next dial out is started almost immediately. The default time
of one second is sometimes too short for the modem or for some telephone exchanges
and the dial out fails. This problem may not be noticed immediately for a scheduled
event since the second event will succeed when it is retried after 10 minutes.
Resolution
A hidden configuration setting controls the time that Pronto waits after
hanging up the modem.
To fix the problem for 32 bit releases 5.00 and later:
- On the Windows taskbar click on START and select RUN.
- Type in REGEDIT and click OK.
- Browse to the section HKEY_LOCAL_MACHINE\Software\Ranger\Pronto for
Windows\Modem\
- Edit or Add the DWORD value DropDTRMillisecs setting it to a value greater
than 1000 (for example 3000).
Note that 32 bit versions of Pronto for Windows may store their configuration
settings on a per user basis instead of per machine. To check if settings
are on a per user basis examine the value of HKEY_LOCAL_MACHINE\Software\Ranger\Pronto
for Windows\User Info\ProfilePerUser if the value is zero then settings are
on a per machine basis otherwise settings are on a per user basis and the DropDTRMillisecs
value must be stored under the key HKEY_CURRENT_USER instead of under HKEY_LOCAL_MACHINE.
To fix the problem for 16 bit releases 4.xx.
- Using NOTEPAD.EXE or some other text editor open the file PRONTO.INI.
This file is normally found in the windows directory.
- Find the section [Modem]
- Edit or Add the value DropDTRMillisecs setting it to a value greater
than 1000 (for example 3000).
- Save the file and exit the editor.
Back to Knowledge Base index
- THE INFORMATION PROVIDED IN THE PRONTO FOR WINDOWS KNOWLEDGE BASE IS
PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. OUTRAM RESEARCH
LTD DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL
OUTRAM RESEARCH LTD OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER
INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS
PROFITS OR SPECIAL DAMAGES, EVEN IF OUTRAM RESEARCH LTD OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL
DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.