back to knowledge base index PROBLEM: Unable to enter Ethernet Configuration Screen using PmScreen.

Last reviewed: July 26, 2011
Article ID: 110726sab

The information in this article applies to:

Symptoms

In PmScreen after clicking Main Menu - Configure - Utilities - Configure Ethernet, the status is shown as Entering Config with the progress arrow. After about 20 seconds the status changes to Starting Up then finally Data Link open and a button Re-enter command mode appear. Clicking on the button or going back and retrying never succeeds. In addition the LED on the module furthest from the lid flashes red about once every second.

Conditions

Both of the following:
1) The Ethernet module is in DHCP mode.
2) The Ethernet cable is not present or the network does not have a DHCP server.

Cause.

Due to a limitation in the Ethernet module, the module never enters command mode (I suspect it is waiting for the DHCP server to issue an IP address).

Resolution

Any of the following:

If solutions 2 or 3 are used the Reset to defaults button on the Configure Ethernet screen should be used to restore the module back to the settings preferred by the PM7000.

Back to Knowledge Base index

Last reviewed: July 26, 2011