PROBLEM: Unable to enter Ethernet Configuration Screen using PmScreen.
Last reviewed: July 26, 2011
Article ID: 110726sab
The information in this article applies to:
- PM7000 with Ethernet option.
Symptoms
In PmScreen after clicking Main Menu
- Configure - Utilities - Configure Ethernet, the status is shown as
Entering Config with the progress arrow. After about 20 seconds the status
changes to Starting Up then finally Data Link open and a button
Re-enter command mode appear. Clicking on the button or going back and
retrying never succeeds. In addition the LED on the module furthest from the
lid flashes red about once every second.
Conditions
Both of the following:
1) The Ethernet module is in DHCP mode.
2) The
Ethernet cable is not present or the network does not have a DHCP server.
Cause.
Due to a limitation in the Ethernet module, the module never enters command
mode (I suspect it is waiting for the DHCP server to issue an IP address).
Resolution
Any of the following:
- Connect the Logger to a Ethernet network with
a DHCP server before trying to configure the module.
- Using the USB or Bluetooth interface, connect to the Logger using TermView
and send the <MoxaReset> command. Either,
Keep
sending the <MoxaStatus> command until the status response is Data
Link open.
or
Wait
twenty seconds then click on the button Re-enter command mode in
PmScreen.
- Press and hold the small red button inside the RJ45 connector on the module,
click on the button Re-enter command mode in PmScreen, wait while the
right hand LED flashes six times and goes out, then release the red button.
Wait a further twenty seconds then click on the button Re-enter command
mode in PmScreen.
If solutions 2 or 3 are used the Reset to defaults button on
the Configure Ethernet screen should be used to restore the module back
to the settings preferred by the PM7000.
Back to Knowledge Base index
- THE INFORMATION PROVIDED IN THE PRONTO FOR WINDOWS KNOWLEDGE BASE IS
PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. OUTRAM RESEARCH
LTD DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL
OUTRAM RESEARCH LTD OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER
INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS
PROFITS OR SPECIAL DAMAGES, EVEN IF OUTRAM RESEARCH LTD OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL
DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.
Last reviewed: July 26, 2011
© 2011 Outram Research Ltd. All rights reserved.