PM7000 Power Quality Analyser

Power Quality Analysers

Find out more about our Power Quality Meters:

  • Easy To Use
  • Reliable Recordings
  • Comprehensive Data Capture
  • Fully Supported

Comparison Chart

Power Quality Analysers

With the wide ranging requirements of our customers from energy audits, to electrical fault finding, power quality troubleshooting, long term data logging, Harmonic Standards compliance, Dynamic Containment provision and prospective fault level measurement to name just a few(!), Outram provide a wide-ranging selection of power quality analysers to match those needs.

We have various options available from single phase energy loggers to 3 phase, comprehensive power quality analysers which can be loaded with extra features such as enhanced G5/5 Harmonics, Fast Frequency and Fault Level measurement. Knowing which one would be the best for your needs might not immediately be obvious so we’ve put together a chart to help.

Either scroll down to your critical measurement parameters and see which models can measure them or pick an analyser along the top and scroll down to see if it fulfils all your requirements. If in doubt, don’t hesitate to give us a call or an email. All details can be found on our contact us page. We’ll be happy to talk you through the different options and find the best unit for your needs.

Comparison Chart

Read Our Reviews

Posted on Google Google
Tower Crescent profile picture
Tower Crescent
29/01/2026
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Fantastic equipment. Brilliant onsite support with their G5/5 and Fault Level Monitor equipment.
Posted on Google Google
Luke Taylor profile picture
Luke Taylor
08/01/2024
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I have had the pleasure of working with the Outram's and their Instruments for over 15 years. Their equipment and hire service has never failed. The technical support is second to none and their friendly approach is always appreciated. I have used many alternatives, but for my needs the Ranger PM equipment is the best by far.
Posted on Google Google
Darren Curtis profile picture
Darren Curtis
27/07/2023
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I needed soem support with my Outram kit, and got it within minutes! Can't fault any of them team, but special thanks to Kate for helping me. May i have many more years of service on my PM3000!
Posted on Google Google
Simon Lynd profile picture
Simon Lynd
08/02/2021
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I have used Outram Research previously for Power Quality Surveys and G5/4 G5/5 compliance issues. All reports were well presented, on time and well laid out technically. Staff are approachable and customer friendly.
Posted on Google Google
Robert King profile picture
Robert King
07/02/2021
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Whilst under contract to Network Rail [RIDC] Midlands Test Facility at Asfordby, Leicestershire. I was required to investigate the impact on Power Quality of the 25kV Traction Testing being undertaken. I researched suppliers of Power Quality Equipment and on discovering the involvement Outram Research Ltd has with the Electricity Supply Industry I recommended NR engage them to assist in the data collection focussed on NPS [voltage unbalance]. I found that Outram Research had a very thorough understanding of all the issues associated with Power Quality and could supply and connect the appropriate Outram Data Loggers to enable the capture of the data I required. With the data captured I was able to demonstrate the .25kV traction testing imposed far less voltage unbalance on the 132kV network than the DNO anticipated. All the Outram staff I engaged with were extremely knowledgeable not only in the data loggers but also in their application. Outram Research downloaded and filed all the data in a logical manner mailing me the information. I have been so impressed with the company and staff that I recommended Outram Research Ltd to the Network Rail Power Quality department describing my experience with them. R H King. C.Eng MIET PowerPhase Services Ltd.
Posted on Google Google
Rob Weller profile picture
Rob Weller
04/02/2021
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Have used Outram equipment for a few years now, for power quality investigation work and G5/4 and G5/5 surveys etc. It is quality kit and with good analysis software. There is also a version capable of fault level monitoring. Most of all, a great company to deal with and fantastic support.
[PM7503] Power Quality Analyser

PM7500

GET A QUOTE
[PM7000] Power Quality Analyser

PM7000

GET A QUOTE
[PM4000] Power Quality Analyser

PM4000

GET A QUOTE
[PM3000] Power Quality Analyser

PM3000

GET A QUOTE
[PM2000] Power Quality Analyser

PM2000

GET A QUOTE
[PM1000] Power Quality Analyser

PM1000

GET A QUOTE

No. Voltage Channels

4 4 4 3 3 1

Voltage Range AC

0-600Vrms or 0-1000Vrms (L-L and L-N). 0-848Vpk or 0-1414Vpk Transient voltages up to 4000V 0-600Vrms or 0-1000Vrms (L-L and L-N). 0-848Vpk or 0-1414Vpk Transient voltages up to 4000V 0-600Vrms or 0-1000Vrms (L-L and L-N). 0-848Vpk or 0-1414Vpk Transient voltages up to 4000V 0-480Vrms or 0-600Vrms 0-678Vpk or 0-848Vpk 0-300Vrms 0-424Vpk 0-270 Vrms 0-381Vpk

Voltage Range DC

0-600Vdc 0-480Vdc

No. Current Channels

4 4 4 3 2 1

Current Range AC

Typical 0-1V RMS. Current to Voltage CTs supplied, nominal input 1A (5A or 10A on special request) 0-400.0A or 0-6000A 0-400.0A or 0-6000A 0-50.00A, 0-400.0A or 0-3000A 0-200A or 0-300A 0-50.00A or 0-1000A

Current Range DC

Variable with relevant current clamps Variable with relevant current clamps

Ability to Measure Neutral

✓ ✓ ✓ ✓ ✓

Differential Voltage Channels

✓ ✓ ✓ ✓

Detailed Recording Channels

32 32 32 16 16 16

General Parameters

✓ ✓

DC Measurement

✓ Optional

Fault Level

Optional Optional

Flicker (Plt, Pst, Pinst, Pflag)

✓ ✓ ✓ ✓ ✓ ✓

Highest order of individual harmonics

50th (127th Optional) 50th (127th Optional) 50th (127th Optional) 15th 15th 15th

Interharmonics

Optional Optional

Enhanced Harmonics to 100th for G5/5 Measurement

✓ ✓

THD and THC

✓ ✓ ✓ ✓ ✓ ✓

kW

✓ ✓ ✓ ✓ ✓ ✓

KVA

✓ ✓ ✓ ✓ ✓ ✓

KVAR

✓ ✓ ✓ ✓ ✓ ✓

Power Factor

✓ ✓ ✓ ✓ ✓ ✓

Unbalance (V & I)

✓ ✓ ✓ ✓ ✓ ✓

Frequency 45-65Hz (Can automatically detect 50 or 60Hz nominal)

✓ ✓ ✓ ✓ ✓ ✓

Fast Frequency Measurement to 0.001Hz resolution

✓ ✓

InRush Current

✓ ✓ ✓ ✓ ✓ ✓

K Factor

✓ ✓ ✓

Symmetrical Components

✓ ✓ ✓ ✓

Single Cycle Adaptive Store

✓ ✓ ✓ ✓ ✓ ✓

Data logging time interval single cycle to 12hrs or Auto-variable with Adaptive Store

✓ ✓ ✓ ✓ ✓ ✓

Sag / Swell / Outage Monitoring

✓ ✓ ✓ ✓ ✓ ✓

High Speed Waveforms with AutoRanking Waveform Capture

Yes at 19.2k Samples/sec Yes at 19.2k, 153.6k, 1.2M Samples/sec Yes at 19.2k Samples/sec

Transient detection

Yes both cycle & sub cycle Yes both cycle & sub cycle Yes both cycle & sub cycle Yes down to single cycle Yes down to single cycle Yes down to single cycle

CBEMA / ANSI / ITIC curve plots

✓ ✓ ✓

Onboard Display

✓

Live Results

Using PMMeter PMWave or PMScreen Using PMMeter PMWave or PMScreen Using PMMeter PMWave or PMScreen Using PMMeter PMWave or PMScreen Using PMMeter or PMScreen Using PMMeter or PMScreen

Bluetooth

✓ ✓ ✓ ✓ Optional ✓

Ethernet

Optional Optional

USB or Infra-Red Communication

USB USB USB USB Infra-Red USB-C

Remote screen with PMScreen

✓ ✓ ✓ ✓ Optional with Bluetooth ✓

Remote Communications via PMGateway

✓ ✓ ✓ ✓ Optional with Bluetooth ✓

Time Synchronisation over mobile phone or PC

✓ ✓ ✓

Memory storage for recorded data

128MB 128MB 32MB 8MB (16MB & 32MB Optional) 1MB 8MB (16MB & 32MB Optional)

Expandable Memory with a memory Stick or Hard Drive

✓ ✓ ✓

Fifo mode

✓ ✓ ✓ ✓ ✓ ✓

Self Powered (powered from Phase A)

✓ ✓ ✓ ✓ ✓ ✓

Can be charged from the mains if necessary (12V DC charger unless otherwise specified)

✓ ✓ ✓ ✓ ✓ Power Lead

Portable/Fixed

F P P P F P

Operating Temperature

-20 to 60°C -20 to 60°C -20 to 60°C -10 to 60°C -30 to 65°C -10 to 60°C

Safety Rating

600V CatIV 600V CatIV, 1000V Cat III (Fuses removed) 600V CatIV, 1000V Cat III (Fuses removed) 600V Cat III 300V Cat III 300V Cat III

IP Rating

IP40 IP65 IP65 IP51 Not applicable IP40

Software

Pronto for Windows Pronto for Windows Pronto for Windows Pronto for Windows Pronto for Windows Pronto for Windows

Speak to us Today

+44 (0) 1243 573050

 

Callback

Make an Enquiry

Quick Contact
The Outram PM7000FLM … software made analysis of fault-current straightforward

We found the Outram PM7000FLM useful for capturing data, and its software made analysis of fault-current straightforward. Other methods of data capture can be used, but would require further development to accurately give fault level information; the area where the FLM scores is its ease of use, and also that statistical analysis is applied over the whole test period, rather than at a ‘snapshot’ of one event as our analysis. This makes it less prone to noise and other disturbances on the system.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project, March 2018
…PM3000 is the best product in my shop

The reason I think your PM3000 is the best product in my shop is the reliability and the software. I use 5 different brands of recorders and this one by far has been the most reliable. The software updates are great, with the 60 day reminders. The layout of the software and every single function make it simple and user friendly unlike most products.

Greg Ellis, Electrical District #3, Arizona USA, 2014
Your kit knocks spots of the bigger manufacturers

Your kit knocks spots of the bigger manufacturers.

Andrew Williams, MD, Smart Electrical Systems, Sept 2018
By far the best project partner I have ever worked with!

Thank you for all the help and support you all gave me on the RTFLM project… It was an absolute privilege to work with you all and Outram are by far the best project partner I have ever worked with!

Cameron Scott, Innovation Engineer, UK Power Networks, 2022
“These [PM7000s] really are pucker units”

Following successful measurements using 2 of our PM7000 Power Quality Hire units…

“We captured some good stuff, these [PM7000s] really are pucker units.”

Shaun Smith, Firstfield Electrical Ltd, March 2021

 

Shaun Smith, Firstfield Electrical Ltd, March 2021
….Commendable for its ease of use and portability

The Outram equipment is commendable for its ease of use and portability.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project
It’s an amazing piece of Kit!

I certainly will be hiring another PM7000 again. It’s an amazing piece of kit!

Stuart Turner, PCAS (Power Control and Automation Solutions) Ltd, Feb 2020
Outram PM7000FLM proved capable of reliably assessing Fault Level

The Outram PM7000FLM and associated software proved to be capable of reliably assessing / calculating fault level from both repeated low-level steps, as well as one-off larger pulses.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project, March 2018
…calculation of fault level trivial in comparison to the ‘manual’ methods

The Outram equipment (and associated software) makes calculation of fault level trivial in comparison to the ‘manual’ methods.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project
I have used data loggers in the past… Not in the same league as the Outram equipment

Thank you for all your fantastic efforts yesterday.

I have used data loggers in the past but they were not in the same league as the Outram equipment.

Last December when Network Rail asked me to install PQ monitoring I looked at hiring a couple of [competitor] PQ monitors. I had a Network Rail Graduate alongside me and I thought it would be a good learning exercise for him. As I began to understand the railway electrification system I realised [these] were a non-starter, so when the local electricity board ‘turned the screw’ I decided to look deeper.

I discovered Outram and when I read about your collaboration with Scottish Power I immediately realised the Outram equipment was the only one to consider. From what I have seen since yesterday morning I know I was correct in contacting your company.

Bob King, Power Phase Services, UK (Contracting for Network Rail)
I have been quite astounded at the detail the Outram Data Logger has captured.

During communications regarding the 3 PM7000TIs that Bob is managing remotely, with new data sent back to him over email every 24 hrs, he told us that he has been finding detail in the recordings he never thought he would see. “I have been quite astounded at the detail the Outram Data Logger has captured.”

Bob King, Power Phase Services, UK
Bluetooth functionality with PMScreen and real time monitoring is sensational.

Thank you so much for attending to [my support query], and so quickly! Very impressed with these [PM3000] power analysers and the Bluetooth functionality with PMScreen and real time monitoring is sensational.

Euan Galbally, Operations Project Engineer - Supply Restoration, SSE.
The analyser did everything that we needed. We were also impressed with how quickly it got across the US.

The analyser did everything that we needed. Rob was surprised at how easily it went on.

We were also impressed with how quickly it got across the US. It was there before we even left [the UK] and we didn’t expect that to happen.

It’s a specialised subject and the support we received from Duncan was second to none.

Chris Brookes, Simpson and Wood, UK Feb 2019
It’s shown me just how much time your software is going to save me!

What you showed me this morning and what I’ve been doing this afternoon has shown me just how much time your software is going to save me!

Bob King, Power Phase Services, UK (Contracting for Network Rail)
That’s a hell of a piece of Kit!

That’s a hell of a piece of Kit!

Now I’ve seen what it can do I’m going to mention it to another customer here in the UK who I know is having trouble.”

Rob Rose, Simpson and Wood, UK Feb 2019
Fault Level Monitors to Validate ENWL RESPOND Project Network models

Fault level monitors – Outram fault level monitors have been installed at seven [Electricity North West] Respond [Project] sites. These monitors will validate our network model and the Fault Level Assessment Tool. Electricity North West Ltd RESPOND Project Newsletter, May 2016.

Electricity North West Ltd RESPOND Project Newsletter, May 2016.
Call Now Button